| 벤치탑 AC 파워미터 GPM-8213

 

제품명 벤치탑 AC 파워미터
모델명 GPM-8213
상세사양

•벤치탑 AC 파워미터, GPM-8213
•디스플레이 : 4인치 TFT LCD
•입력 전압/전류 : 600Vrms/20Arms
•입력 전력 : 75mW~12kW
•입력 주파수 : DC/45Hz~6kHz

인터페이스 •RS-232/USB/LAN, GPIB(옵션)
브랜드 GWINSTEK
판매가격 전화문의 : ☎070-4333-8982
배송비 주문시 결제

상품 기본설명

벤치탑 AC 파워미터 GPM-8213

제품사양

주요 특징

• 4” TFT LCD

• Two data display modes

• Standard : two major measurement items + six secondary measurement items

• Simple : displaying test data of four different measurement items

• Met the requirement of IEC 62301 power measurement

• Voltage/ current test frequency bandwidth : DC~6kHz

• Watt resolution : 1mW

• Lowest current range : 5mA, resolution : 0.1uA

• Current/voltage measurements reach CF=3 for distorted wave and CF=6 for half range

• W-h (power vs time)/A-h (current vs time) integration function

• Total harmonic distortion measurement

• Front panel test terminal

• Standard interface : RS-232C, USB device, LAN

• Optional interface : GPIB

• Optional test fixture : GPM-001

 

GW Instek GPM-8213 power meter is designed specifically for single-phase (1P/2W) AC power supply’s power measurements. Powerful features, including 4” TFT LCD, five-digit measurement display, 19 power measurement parameters, integral measurement function, high-accuracy voltage/current/power measurement capabilities, front/rear panel input terminals, and various communications ports, are to facilitate users with clear, convenient, and accurate power measurements.

 

GPM-8213 provides as many as 19 power measurement parameters, including voltage (Vrms/ V+pk / V-pk), current (Irms/ I+pk / I-pk), frequency (VHz/ IHz), power (P/ P+pk / P-pk), crest factor (CFV/ CFI), apparent power (VA), reactive power (VAR), power factor (PF), phase angle (DEG), total harmonic distortion (THDV/ THDI), high-accuracy voltage/current/power measurement capabilities (reading: ±0.1%; level: ±0.1%). The advantages of TFT LCD havebeen efficiently deployed to simple mode and standard mode. Simple mode displays conventional power meter’s four measurement parameters to meet the requirement of accuracy and clarity for the test on manufacturing process. Standard mode extends the display to the maximum of 8 measurement parameters (2 major measurements + 6 monitor measurements) to satisfy the various measurement application requirements of R&D, design, and quality verification.

 

For DUT requiring IEC 62301/EN 50564 standby power consumption test, GPM-8213 provides the optimal measurement supports, including test frequency bandwidth of DC~6kHz, the minimum current level of 5mA (resolution: 0.1uA), power measurement resolutions (1uW for minimum current and voltage levels; 1mW for maximum current and voltage levels), crest factor reaching 3 (half range reaching 6), and measurement of total harmonic distortion (at least 13th orderpower harmonic). For large voltage /large current measurement applications of general power measurement, GPM-8213 provides PT / CT rate function to collocate with external potential transformer or current transformer to meet the measurement requirements.

 

With respect to data retrieval and storage, the standard RS-232C/ USB interfaces (virtual COM)/ LAN can be utilized to edit and retrieve programs or the optional GPIB interface (installed by manufacturer) can be selected to meet users’ automatic test system requirements.

 

Two Display Modes  

GPM-8213 provides two display modes so as to maximize users’ measurement effectiveness.

 

Standard mode: simultaneously displays 8 measurement parameters (2 major measurements + 6 secondary measurements) and related measurement setting parameters; ideal for R&D, design, and engineering verification.

Simple mode: displays four measurement parameters; ideal for production tests.

1.jpg

 

Standard mode

(Setting & 8 measurement)

2.jpg

 Simple mode

 

(4 measurements)

 

Variety of Measurement Parameters

Comparing with products of the same category, GPM-8213 provides more diverse measurement items and functions, including voltage, current, frequency, active power, apparent power, reactive power, power factor, crest factor, and total harmonic distortion measurement. GPM-8213 also features the integral measurement function for DUT’s power or current time. Users can set a time period to execute the transient power integration and divide the result by timeto receive DUT’s average power.

 

 

3.jpg

 

 

 

4.jpg

 

 

 

Optional Measuement Capabilities

For IEC 62301/EN 50564 standby power consumption test requirement, GPM-8213 can fully meet the demand by its features, including measurement frequency bandwidth of DC~6kHz, minimum current level of 5mA (resolution: 0.1uA), power measurement resolutions (1uW for minimum current and voltage levels; 1mW for maximum current and voltage levels). Beyond that, time resolution for integral measurement is one second. With respect to large power measurement, userscan utilize terminal on the rear panel to conduct 600V / 20A measurement. Users can also use external potential transformer/current transformer for measurement and collocate with PT/CT to set multiplying factor (1~9999) to change readings to the original input voltage or current values without the trouble of additional calculation.

6.jpg

 

Low current range & High resolution


7.jpg

PT / CT Connection

 

 

Various Standard Interfaces

The various practical interfaces, RS-232 / USB device/ LAN, are equipped as standard making control convenient and flexible for remote control and measurement result collection. Also, GPIB is available as optional.

.

Specification

Input

Item

Spec.

Input voltage

600 Vrms

Input current

20 Arms

Input impedance

(50/60 Hz)

Voltage

2.4MΩ

Current

5mA~200mA

500mΩ

0.5A~20A

5mΩ

Maximum display voltage

700 Vrms

Maximum display current

25 Arms

Maximum allowable isolation voltage

300 V

Low frequency filter

Cut-offfrequency

500 Hz 

Display

Synchronization frequency

45Hz~ 6kHz

Average

1, 2, 4, 8, 16,32, 64

Displayed items(Standard mode)

8 itemssimultaneously.

Displayed items(Simple mode)

4 itemssimultaneously.

Displayed digits

5

Voltage converter (PT ratio)

1 to 9999.999

Current converter (CT ratio)

1 to 9999.999

Measurement items

Voltage,current, active power, apparent power, reactive power, power factor, phaseangle, frequency, integrated current, integrated power, positive integratedpower, negative integrated power, integration time, voltage crest factor,current crest factor, voltage peak, current peak, Thd

Displayed measurement parameters

Vdc, Vrms,V+pk, V-pk, Idc, Irms, I+pk, I-pk, P, P+pk, P-pk, VA, VAR, PF, CFV, CFI, DEG,VHz, IHz, THDV, THDI

VoltageMeasurement

Measurement range

CF=3 :

15V, 30V, 60V,150V, 300V, 600V

CF=6 :

7.5V, 15V, 30V,75V, 150V, 300V

Crest factor

3, 6

Accuracy

Effective range

1 %to 105 % of range

DC

±(0.2% reading  +  0.2 % range)

45 Hz ≤ f ≤ 66 Hz

±(0.1% reading  +  0.1 % range)

66 Hz < f ≤ 1kHz

±(0.1% reading  +  0.2 % range)

1 kHz < f ≤ 6kHz

± 3 %of range

The filter is turned on

Increase0.3 % reading@ 45Hz to 66Hz 

Temperature effect

5-18˚C / 28-40˚C

Increase±0.03% reading /˚C

Residual noise

0.5 %of range

Current Measurement

Measurement range

CF=3 :

5mA, 10mA, 20mA,50mA, 100mA, 200mA, 500mA, 1A, 2A, 5A, 10A, 20A 

CF=6 :

2.5mA, 5mA, 10mA,25mA, 50mA, 100mA, 250mA, 0.5A, 1A, 2.5A, 5A, 10A 

Crest factor

3, 6

Accuracy

Effective range

1 %to 105 % of range

DC

±(0.2% reading  +  0.2 % range)

45 Hz ≤ f ≤ 66 Hz

±(0.1% reading  +  0.1 % range)

66 Hz < f ≤ 1kHz

±(0.1% reading  +  0.2 % range)

1 kHz < f ≤ 6kHz

± 3 %of range

The filter is turned on

Increase0.3 % reading@ 45Hz to 66Hz 

Temperature effect

5-18˚C / 28-40˚C

Increase±0.03% reading /˚C

Residual noise

0.5 %of range

Power Measurement

Accuracy

Effective range

1 % to 110 % ofrange

DC

±(0.2 %reading  +  0.2 % range)

45 Hz ≤ f ≤ 66 Hz

±(0.1 %reading  +  0.1 % range)

66 Hz < f ≤1kHz

±(0.1 %reading  +  0.3 % range)

1 kHz < f ≤6kHz

± 3 % of range

The filter isturned on

Increase 0.3 %reading@ 45Hz to 66Hz 

Temperature effect

5-18˚C / 28-40˚C

Increase ±0.03%reading /˚C

Frequency Measurement

Measurement range 

Thefilter is turned on

30.000Hz to499.99Hz

The filter is turned off

30.000Hz to9.9999kHz

Measurement items

Voltage,Current 

Effective input range

10% to 105% ofvoltage input range 

Accuracy

±(0.06 %reading)

Integrator Measurement

Integrator 

Accuracy

±(Accuracy ofvoltage or current+ 0.1 % reading)

Time

Range

0 hour 0 minuteto 9999 hours 59 minutes

Accuracy

±0.01% ±1second

Specification Condition

Temperature:23˚C±5˚C

Humidity: <80%RH(non-condensing)

Operation Condition

Temperature 0°C~ 40°C,

30 ~ 40°C, Relative Humidity < 70%RH(non-condensing)

·     >40°C, Relative Humidity < 50%RH(non-condensing)

Storage Condition

Temperature−40°C ~ 70°C

Humidity < 90%RH(non-condensing)

Power Source

AC 100-240V,50–60Hz ; Consumption Max. 25VA

Dimension & Weight

270(W) x 110(H)x 350(D) mm, Approx. 2.9kg

* The specifications apply whenthe GPM is warmed up for at least 30 minutes.

* Below are the basicconditions required to operate the GPM within specifications:

1-year calibration cycle

All specification are ensured under SLOW speed

Accuracy: ± (%of reading+ %of range)

The power cord protective grounding conductor must be connectedto ground

Input voltage/current should be sinewave

Power factor is 1

Crest factor is 3

Common mode voltage is 0

.

.

 

라인업

주문 정보

GPM-8213

Digital Power Meter with RS-232C/USB device/LAN

견적요청

GPM-8213G

Digital Power Meter with RS-232C/USB device/LAN/GPIB

견적요청

 

 

기본 액세서리

Safety Instruction Sheet x 1, Power cord x 1, Test lead GTL-209 x 1, CD x 1 (including complete user manual and USB driver)

옵션

옵션.01

GPIB 인터페이스 (공장 출하 설치)

옵션 액세서리

GPM-001

Test Fixture (with connection cable)

GTL-232

RS-232C cable, 9-pin Female to 9-pin, null modem for computer, Approx. 2000mm

GTL-246

USB Cable, A-B type, Approx. 1200mm

GTL-248

GPIB Cable, Approx. 2000mm

GTL-251

GPIB-USB-HS+ (high speed)

 

옵션 액세서리

GPM-001

Test Fixture (with connection cable)

견적요청

GTL-232

RS-232C cable, 9-pin Female to 9-pin, null modem, Approx. 2000mm

11,000원

GTL-246

USB Cable, A-B type, Approx. 1200mm

14,000원

GTL-248

GPIB Cable, Approx. 2000mm

195,000원

GTL-248

GPIB-USB-HS+ (high speed)

1,829,000원

 

 

상기 가격은 부가세 별도 가격입니다.

다운로드







*** 본 (주)파워티엠 홈페이지의 게시물 및 제품 자료를 사전 동의없이 무단으로 복사 및 배포를 금지합니다. ***


이 분류에 등록된 다른 상품이 없습니다. 전체목록 ▲ 맨위로 ◀◀ 뒤로가기

상품 정보

상품문의

  • 상품정보
  • 상품문의 0
  • 배송정보
  • 관련상품 0
  • 등록된 상품문의

    상품문의가 없습니다.

배송정보

  • 상품정보
  • 상품문의 0
  • 배송정보
  • 관련상품 0
  • ★ 배송정보 ★
    1. 재고 보유상품의 경우 입금확인 후 1~3일 정도 상품 준비기간이 소요되며, 주문량이 많을 경우
        준비기간이 조금 더 소요될 수 있습니다. 
        (단, 재고 소진 상품의 경우 배송기간이 3주~4주 소요될수 있사오니 참고바랍니다.)
    2. 주문하신 상품은 배송완료 문자를 받아보신 후 1~2일 이내에 수령하실 수 있습니다.
    3. 10만원 이상 구매시 배송료는 무료입니다.
    ※ 해외배송은 무료배송이벤트에서 제외됩니다.해외배송 상품무게는 별도 측정 후
        주문상품 구매액 + 운임료와 함께 결제해주셔야 합니다.

     

관련상품

 

 

 

회사소개

 

전력전자 제품

 

계측기기 제품

 

ATE(시스템)

 

자료실(다운로드)

 

고객지원

인사말

회사소개

회사연혁

주요거래처

오시는길

DC전원공급기(국내Brand)

DC전원공급기(수입Brand)

양방향/회생형 전원장치

전자로드(전자부하기)

AC전원공급기(파워소스)

로드뱅크(LOAD BANK)

SMPS/컨버터/인버터

오실로스코프

디지털멀티메터

스펙트럼분석기

클램프메터(전류계)

파워메터(전력분석기)

제네레이터/파형발생기

저항계 / LCR메터

내전압/절연저항 시험기

데이터로거/레코더/DAQ

열화상카메라

기타 계측기

단종제품

배터리 충방전시스템

자동차 부품 시험기

태양광발전 시험기

반도체 시험기

OLED / LED 시험기

전기전자부품 수명 시험기

원자력발전/중이온가속기시험

방위산업 관련 시험기

매뉴얼 자료실

프로그램 자료실

카타로그 자료실

사양서 자료실

기술 자료실

공지사항

이벤트게시판

1:1문의

온라인 A/S요청

교정접수안내

교정신청서

 

견적요청

온라인 견적요청

업체명: (주)파워티엠 | 대표자: 차효정 | 주소: 경기도 성남시 중원구 사기막골로 124 , 비즈센터동505호(상대원동,SKn테크노파크)
문의전화(Tel): 070-4333-8982 | 팩스(Fax): 070-7966-8928 | e메일: powertm@powertm.co.kr
사업자등록번호: 215-87-96171 | 통신판매업신고: 제2016-성남중원-0113호
Copyright © (주)파워티엠. All Rights Reserved.